Overhead XLPE Insulated Aerial Bundle Cable-ABC
Product Description
1. Rated Voltage: 0.6/1KV.
2. Conductor: Pure annealed copper or aluminum.
3. Insulation: XLPE/PE/PVC.
4. Cores: 1 C, 2C, 3C, 4C.
5. Nominal Cross-section: 10mm2 to 400mm2.
6. Standard: GB/T 14049-2008 IEC 60502.
7. Max. Operating Temperature: XLPE/PE: 90 °C , PVC : 70 °C .
8. Type: ABC Cable, JKTRYJ, JKLYJ,JKTRY, JKLY, JKLGYJ, JKLGY, JKLYJ/Q, JKLY/Q, JKLGYJ/Q, JKLGY/Q.
9.Packing: Wooden Drum or according to the customer requirement.
10.Remark: The cable can be of flame retardant, fire resistance and other property.
Used to supply power,usually from a pole-mounted transformer, to the user"s service head where connection to the service entrance.
To be used at 600V or less phase to phase and at conductor temperatures not to exceed 75°C for polyethy insulated or 90°C for crosslinked.
ABC Cable, Aerial Bundled Cable, 0.6/1 KV (BS 7870-5)
Product Description
Low Voltage Aerial Bundled Cable/ Low Voltage ABC Cable
The basic construction is as follows:
3 power cores consisting of standard aluminium conductors, insulated withXLPE insulation
+ One sheath lighting aluminium conductor with XLPE insulation(optional)
+ One messenger Al-alloy conductor (bare or covered)
The messenger conductor can be of galvanised steel wire also.
The purpose of messenger wire is
A) It acts as load bearing wire.
B) It acts as earth or neutral conductor.
To be used at cotages of 600V phase-to-phase or less and at conductor temperatures not to exceed 75oC for polyethylene insulated conductors or 90oC for crossliked polyethylene(XLPE) insulated conductors.
Standards:
(1). BS 7870-5: Part 5: Polymeric insulated aerial bundled conductors (ABC) of rated voltage 0.6/1 kV for overhead distribution
ABC Cables without Street Lighting |
1+1 Structure |
Phase Conductor | Neutral Conductor | Completed Cable |
Section | Insulation Thickness | Electrical Resistance | Section | Insulation Thickness | Electrical Resistance | Overall Diameter | Cable Weight |
DC.20°C | DC.20°C | | |
No.xmm2 | mm | Ω/km | mm2 | mm | Ω/km | mm | kg/km |
1x25 | 1.3 | 1.20 | 25 | 1.3 | 1.20 | 17.6 | 210 |
1x35 | 1.3 | 0.868 | 35 | 1.3 | 0.868 | 19.6 | 270 |
1x50 | 1.5 | 0.641 | 50 | 1.5 | 0.641 | 23 | 360 |
1x70 | 1.5 | 0.443 | 70 | 1.5 | 0.443 | 26.4 | 500 |
1x95 | 1.7 | 0.320 | 95 | 1.7 | 0.320 | 30.6 | 680 |
| | | | | | | |
3+1 Structure |
Phase Conductor | Neutral Conductor | Completed Cable |
Section | Insulation Thickness | Electrical Resistance | Section | Insulation Thickness | Electrical Resistance | Overall Diameter | Cable Weight |
DC.20°C | DC.20°C | | |
No.xmm2 | mm | Ω/km | mm2 | mm | Ω/km | mm | kg/km |
3x25 | 1.3 | 1.20 | 25 | 1.3 | 1.20 | 21.2 | 410 |
3x35 | 1.3 | 0.868 | 35 | 1.3 | 0.868 | 23.7 | 550 |
3x50 | 1.5 | 0.641 | 50 | 1.5 | 0.641 | 27.8 | 730 |
3x70 | 1.5 | 0.443 | 70 | 1.5 | 0.443 | 31.9 | 1000 |
3x95 | 1.7 | 0.320 | 95 | 1.7 | 0.320 | 36.9 | 1370 |
3x120 | 1.7 | 0.253 | 120 | 1.7 | 0.253 | 40.6 | 1690 |
ABC Cables with Street Lighting |
3+1+1 Structure |
Phase Conductor | Neutral Conductor | Street Lighting Conductor | Completed Cable |
Section | Insulation Thickness | Section | Insulation Thickness | Section | Insulation Thickness | Overall Diameter | Cable Weight |
|
No.xmm2 | mm | mm2 | mm | mm2 | mm | mm | kg/km |
3x50 | 1.5 | 50 | 1.5 | 25 | 1.3 | 29.8 | 830 |
3x70 | 1.5 | 70 | 1.5 | 25 | 1.3 | 33.6 | 1100 |
3x95 | 1.7 | 95 | 1.7 | 25 | 1.3 | 38.2 | 1470 |