Model NO.
yjv/yjv32/yjv22/yjv42/yjv72
Application
Overhead, Heating, Underground, Machine Equipment
Conductor Material
Copper
Material Shape
Round Wire
Range of Application
Flame Retardant
Certification
ISO9001, CE, UL, CCC, RoHS, VDE, Soncap,SAA,PSE,Kcktl,Saso
Rated Voltage:0.6/1kv up to 500kv
XLPE Insulated PVC Sheath Cable
Steel Wire Armoured XLPE Power Cable
Steel Tape Armoured XLPE Power Cable
Electrical Cable
Power Cable
XLPE Insulated Power Cable with Rated Voltage up to 35 kV
Application
This product is fit for power transmission with rated voltage up to 35 kV.
Type and Designation
Basic type	Designation	Standard
Copper core	Al core		
YJV
YJY
YJV22
YJV32
YJV42
YJV62
YJV72
YJLV
YJLY
YJLV22
YJLV32
YJLV42
YJLV62
YJLV72
XLPE insulated PVC sheathed power cable
XLPE insulated PE sheathed power cable
XLPE insulated steel tape armoured PVC sheathed power cable
XLPE insulated fin steel wire armoured PVC sheathed power cable
XLPE insulated fine steel wire armoured PVC sheathed power cable
XLPE insulated dual non-magnetic metal tape armoured PVC sheathed power cable
XLPE insulated non-magnetic metal tape armoured PVC sheathed power cable	IEC60502-2
GB/T12706.2~. 3
Speicfication
Type	Number of core	Rated voltage Uo/U kV
		3.6/6\6/6	6/10\8.7/10\8.7/15	12/20	18/30\21/35\26/35
		Nominal cross-section mm2
YJV
YJY
YJV62
YJV72	YJLV
YJLY
YJLV62
YJLV72	1	25~630	25~630	35~630	50~630
YJV
YJY
YJV22
YJV32
YJV42
YJV62
YJV72	YJLV
YJLY
YJLV22
YJLV32
YJLV42
YJLV62
YJLV72	3	25~500	25~500	35~500	50~500
Structure Figure
Insulation thickness
Nominal cross-section
Mm2	Nominal insulation thickness at rated voltage
Mm
3.6/6(7.2)kV	6/6(7.2) kV
6/10(12) kV	8.7/10(12) kV
8.7/15(17.5) kV	12/20(24) kV	18/30(36) kV	21/35(40.5) kV	26/35(40.5) kV
25
35
50~185
240
300
400
500~1000	2.5
2.5
2.5
2.6
2.8
3.0
3.2	3.4
3.4
3.4
3.4
3.4
3.4
3.4	4.5
4.5
4.5
4.5
4.5
4.5
4.5	
5.5
5.5
5.5
5.5
5.5
5.5	
8.0
8.0
8.0
8.0
8.0
9.3
9.3
9.3
9.3
9.3	
10.5
10.5
10.5
10.5
10.5
Technical parameter
First, D. C resistance of the conductor can comply with regulation in IEC60228\GB/T3956.
Second, (mF/km)Inductance and earthing capacitance.
1. )Inductance and capacitance of single cable
Nominal cross-section
Mm2	Voltage rating kV
	3.6/6	6/6\6/10	8.7/10\8.5/15	12/20	18/30	21/35	26/35
	inductance	capacitance	inductance	capacitance	inductance	capacitance	inductance	capacitance	inductance	capacitance	inductance	capacitance	inductance	capacitance
25
35
50
70
95
120
150
185
240
300
400
500
630	
0.240
0.408
0.385
0.366
0.344
0.331
0.315
0.308
0.301
0.296
0.295
0.288
0.281
0.24
0.26
0.30
0.34
0.38
0.42
0.46
0.50
0.54
0.56
0.61
0.68
0.76
0.433
0.411
0.398
0.379
0.354
0.344
0.334
0.322
0.313
0.302
0.299
0.291
0.283
0.19
0.21
0.24
0.27
0.30
0.32
0.35
0.38
0.42
0.47
0.55
0.63
0.71	
0.449
0.427
0.414
0.392
0.369
0.360
0.350
0.341
0.325
0.314
0.309
0.298
0.289
0.15
0.18
0.19
0.22
0.24
0.26
0.28
0.30
0.34
0.37
0.41
0.45
0.51	
0.459
0.436
0.414
0.392
0.379
0.366
0.350
0.341
0.328
0.318
0.307
0.298
0.16
0.17
0.19
0.21
0.23
0.25
0.27
0.29
0.32
0.36
0.41
0.45
0.448
0.432
0.413
0.394
0.398
0.375
0.361
0.341
0.332
0.328
0.312	
0.13
0.15
0.16
0.17
0.19
0.20
0.22
0.24
0.26
0.32
0.34
0.467
0.455
0.436
0.417
0.404
0.392
0.376
0.360
0.347
0.355
0.339
0.12
0.14
0.15
0.16
0.17
0.18
0.20
0.22
0.23
0.25
0.30	
0.513
0.487
0.465
0.446
0.430
0.417
0.394
0.373
0.361
0.354
0.342	
0.11
0.12
0.13
0.14
0.15
0.16
0.18
0.19
0.21
0.23
0.26
1. )Inductance and capacitance of 3core cable
Nominal cross-section
Mm2	Voltage rating kV
	3.6/6	6/6\6/10	8.7/10\8.5/15	12/20	18/30	21/35	26/35
	inductance	capacitance	inductance	capacitance	inductance	capacitance	inductance	capacitance	inductance	capacitance	inductance	capacitance	inductance	capacitance
25
35
50
70
95
120
150
185
240
300
400
500	0.363
0.351
0.331
0.314
0.301
0.289
0.280
0.273
0.266
0.263
0.259
0.254	0.70
0.78
0.90
1.02
1.14
1.26
1.38
1.50
1.62
1.68
1.83
1.91	0.395
0.376
0.357
0.336
0.322
0.309
0.299
0.291
0.281