    Housing 1, 2 & 3 Number Code
    C–8–3 1/4” BSPP 02–160739 (A)2G
     3/8” BSPP 02–160740 (A)3G
     SAE 4 02–160741 (A)4H
     SAE 6 02–160742 (A)6H
    C–10–3 1/4” BSPP 876705 (A)2G
     3/8” BSPP 876714 (A)3G
     SAE 6 876704 (A)6H
     SAE 8 876711 (A)8H
    C–10–3S 1/4” BSPP 876707 (A)2G
     3/8” BSPP*** 876710 (A)3G
     SAE 6 876706 (A)6H
     SAE 8** 876712 (A)8H
    C–12–3 1/2” BSPP 02–161817 (A)4G
     3/4” BSPP 02–161816 (A)6G
     SAE 10 02–160642 (A)10H
     SAE 12 02–160646 (A)12H
    C–12–3S 1/2” BSPP* 02–178270 (A)4G
     3/4” BSPP* 02–178271 (A)6G
     SAE 10** 02–178268 (A)10H
     SAE 12** 02–178269 (A)12H
    Notes
    BSPP porting is designated by
    ‘‘G” in the model code SAE
    porting is designated by either
    “H” or “T’’ in the model code.
     Ports Part
    Housing 1, 2 & 3 Number Code
    C–16–3 1/2” BSPP 876720 (A)4G
     3/4” BSPP 876722 (A)6G
     SAE 10 876721 (A)10H
     SAE 12 876723 (A)12H
    C–16–3S 1/2” BSPP 02–160676 (A)4G
     3/4” BSPP 876726 (A)6G
     SAE 10 876725 (A)10H
     SAE 12 876727 (A)12H
    C–20–3 1/2” BSPP 876737 (A)4G
     3/4” BSPP*** 876738 (A)6G
     SAE 10 876757 (A)10H
     SAE 12 876739 (A)12H
    C–20–3S 3/4” BSPP 876740 (A)6G
     1” BSPP 876742 (A)8G
     SAE 12 876741 (A)12H
     SAE 16 876743 (A)16H
    * Port 3 = 3/8” BSPP
    ** Port 3 = SAE 6
    *** Port 3 = 1/4” BSPP
    J
    C
    B
    H
    G
    A
    D
    E
    F
    1
    2
    3
    I
    Only for C-12-3*
    Two holes ?10.3(0.04),
    (82,5) 3.250 apart
    Note
    Fatigue rated aluminum housings
    are intended for applications
    up to 210 bar (3000 psi)
    with harsh duty cycles. These
    housings have been fatigue
    rated to NFPA standards to one
    million cycles.
    C-**-3/3S
    Aluminum housings
    (NFPA fatigue rated)
    .B
    J
    J-8.A EATON Screw-In Cartridge Valves E-VLSC-MC001-E1 September 2013
    Where measurements are critical request certified drawings. We reserve the right to change specifications without notice.
     Ports Part
    Housing 1, 2 & 3 Number Code
    C–8–3 1/4” BSPP 02–160743 (S)2G
     3/8” BSPP 02–160744 (S)3G
     SAE 4 02–160745 (S)4T
     SAE 6 02–160746 (S)6T
    C–10–3 1/4” BSPP 02–175127 (S)2G
     3/8” BSPP 02–175128 (S)3G
     SAE 6 02–175124 (S)6T
     SAE 8 02–175125 (S)8T
    C–12–3 1/2” BSPP 02–169815 (S)4G
     3/4” BSPP 02–169814 (S)6G
     SAE 10 02–161070 (S)10T
     SAE 12 02–169816 (S)12T
    C–16–3 1/2” BSPP 02–175131 (S)4G
     3/4” BSPP 02–175132 (S)6G
     SAE 10 02–175129 (S)10T
     SAE 12 02–175130 (S)12T
    C–20–3 3/4” BSPP 02–175135 (S)6G
     1” BSPP 02–175136 (S)8G
     SAE 12 02–175133 (S)12T
     SAE 16 02–175134 (S)16T
    Notes
    BSPP porting is designated by
    ‘‘G” in the model code SAE
    porting is designated by ‘‘T’’ in
    the model code.
    Notes
    Fatigue rated steel
    housings are intended for applications
    up to 350 bar (5000 psi)
    with harsh duty cycles. These
    housings have been fatigue
    rated to NFPA standards to one
    million cycles.
    Dimensions A B C D E F G H I J K Mass
    mm (inch) kg (lb)
    C-8-3* 63,5 31,8 66,7 38,1 19,1 15,5 54,0 3,3 56,9 7,1 29,8 0,9
     (2.50) (1.25) (2.63) (1.50) (0.75) (0.61) (2.13) (0.13) (2.24) (0.28) (1.17) (2.15)
    C-10-3 76,2 38,1 76,2 44,4 22,4 19,1 63,5 9,7 57,0 7,1 35,1 1,7
     (3.00) (1.50) (3.00) (1.75) (0.88) (0.75) (2.50) (0.38) (2.24) (0.28) (1.38) (3.75)
    C-12-3 88,9 44,4 101,6 50,8 25,4 28,7 88,9 12,7 63,5 10,3 51,5 3,0
     (3.50) (1.75) (4.00) (2.00) (1.00) (1.13) (3.50) (0.50) (2.50) (0.40) (2.03) (6.75)
    C-16-3 101,6 50,8 107,9 50,8 25,4 25,4 88,9 12,7 76,2 10,3 54,0 3,4
     (4.00) (2.00) (4.25) (2.00) (1.00) (1.00) (3.50) (0.50) (3.00) (0.40) (2.13) (7.70)
    C-20-3 114,3 57,1 139,7 63,5 31,8 31,8 114,3 19,0 76,2 11,9 72,2 6,4
     (4.50) (2.25) (5.50) (2.50) (1.25) (1.25) (4.50) (0.75) (3.00) (0.47) (2.84) (14.30)
    * 8 Series housings utilize a slot instead of mounting holes.
    I
    B
    D
    E
    H J?
    F
    G
    1
    3
    2
    C
    A
    K
    C-**-3
    Steel housings
    (NFPA fatigue rated)
    J
     EATON Screw-In Cartridge Valves E-VLSC-MC001-E1 September 2013 J-9.A
    Where measurements are critical request certified drawings. We reserve the right to change specifications without notice.
    I
    I
    1
    C-16 & -20
    B
    D
    H
    J
    F
    G
    F
    H
    G J
    L?
    K
    L?
    C
    B
    D
    C-10 & -12
    E
    2
    3 3
    2
    1
    C
    A A
    K
    E
     Part
    Housing Ports 1 & 2 Port 3 Number Code
    C–10–3S 3/8” BSPP 1/4” BSPP 02–163313 (S)3G
     1/2” BSPP 1/4” BSPP 02–163324 (S)4G
     SAE 6 SAE 6 02–171961 (S)6T
     SAE 8 SAE 6 02–163322 (S)8T
     SAE 10 SAE 6 02–163323 (S)10T
    C–12–3S 1/2” BSPP 3/8” BSPP 02–160994 (S)4G
     3/4” BSPP 3/8” BSPP 02–160995 (S)6G
     SAE 10 SAE 6 02–160996 (S)10T
     SAE 12 SAE 6 02–160997 (S)12T
    C–16–3S 1/2” BSPP 3/8” BSPP 02–175118 (S)4G
     3/4” BSPP 3/8” BSPP 02–175119 (S)6G
     SAE 10 SAE 6 02–175116 (S)10T
     SAE 12 SAE 6 02–175117 (S)12T
    C–20–3S 3/4” BSPP 3/8” BSPP 02–175122 (S)6G
     1” BSPP 3/8” BSPP 02–175123 (S)8G
     SAE 12 SAE 6 02–175120 (S)12T
     SAE 16 SAE 6 02–175121 (S)16T
    Notes
    BSPP porting is designated by
    ‘‘G” in the model code SAE
    porting is designated by ‘‘T’’ in
    the model code.
    Fatigue rated steel housings
    are intended for applications
    up to 350 bar (5000 psi) with
    harsh duty cycles. These housings
    have been fatigue rated to
    NFPA standards to one million
    cycles.
    Dimensions A B C D E F G H I J K L? Mass
    mm (inch) kg (lb)
    C-10-3S 63,5 31,8 76,2 41,3 20,7 36,6 53,8 11,2 53,8 9,7 19,8 8,7 1,08
     (2.50) (1.25) (3.00) (1.63) (0.82) (1.44) (2.12) (0.44) (2.12) (0.38) (0.78) (0.34) (2.40)
    C-12-3S 88,9 44,5 101,6 50,8 25,4 41,9 76,2 31,7 57,1 12,7 23,1 10,3 2,4
     (3.50) (1.75) (4.00) (2.00) (1.00) (1.65) (3.00) (1.25) (2.25) (0.50) (0.91) (0.40) (5.40)
    C-16-3S 88,9 41,2 88,9 50,8 25,4 38,1 69,8 12,7 63,5 19,0 17,4 10,3 2,6
     (3.50) (1.62) (3.50) (2.00) (1.00) (1.50) (2.75) (0.50) (2.50) (0.75) (0.68) (0.40) (5.90)
    C-20-3S 101,6 44,4 114,3 63,5 31,7 50,8 88,9 12,7 76,2 25,4 20,6 10,3 4,6
     (4.00) (1.75) (4.50) (2.50) (1.25) (2.00) (3.50) (0.50) (3.00) (1.00) (0.81) (0.40) (10.24)
    C-**-3S
    Steel housings
    (NFPA fatigue rated)
    J
    J-10.A EATON Screw-In Cartridge Valves E-VLSC-MC001-E1 September 2013
    Where measurements are critical request certified drawings. We reserve the right to change specifications without notice.
     2
    F A
    (2 places)
    J
    Port
    E
    C
     B
    "2"
    D
    G
    C
    G
    Port 2
    ?H
    (2 places)
    F A
    (2 places)
    ?H
    (2 places)
    Housing Number
     Aluminum Steel
    Code Port Size EPV16-A EPV16-B EPV16-A EPV16-B
    4G 1/2” BSPP 02-185448 02-166607 02-180050 02-165500
    6G 3/4” BSPP 02-185449 02-161582 02-180051 02-164931
    10H SAE 10 02-185446 02-170238 – –
    12H SAE 12 02-185447 02-166609 – –
    10T SAE 10 – – 02-180048 02-161983
    12T SAE 12 – – 02-180049 02-161982
    5C CETOP5 (NFPA D05) interface (Requires steel housing)
    Model A B C D E F G ?H J Mass kg (lb)
    mm (inch) Alum Steel
    Modified C-16-3S 76,2 30,2 79,2 100,8 38,1 12,7 21,4 8,7 60,4 2,0 6,0
    body (3.00) (1.19) (3.12) (3.97) (1.50) (0.50) (0.84) (0.34) (2.38) (4.50) (13.5)
    For use with EPV16-A or B only.
    Modified housing for
    use with EPV16-A.
    Modified housing for
    use with EPV16-B.
    C-16-3S
    Steel (NFPA fatigue rated)
    Special housings for EPV16 only
    J
     EATON Screw-In Cartridge Valves E-VLSC-MC001-E1 September 2013 J-11.A
    Where measurements are critical request certified drawings. We reserve the right to change specifications without notice.
     Ports 1, Part
    Housing 2, 3 & 4 Number Code
    C–10–4 3/8” BSPP 02-179705 (A)3B
     SAE 6 566161 (A)6T
    C–12–4 SAE10 6030517-001 (A)10T
    C–16–4 3/4” BSPP 02-175468 (A)6B
     SAE 12 566411 (A)12T
    C–20–4 1” BSPP 02-175469 (A)8B
     SAE 16 566412 (A)16T
    Housing (FDC*-**only)
    C–10–4 3/8” BSPP 02-175467 (A)3B
     SAE 6 566234 (A)6T
    C–16–4 3/4” BSPP 02-175468 (A)6B
     SAE 12 566200 (A)12T
    Notes
    BSPP porting is designated by
    ‘‘B” in the model code SAE
    porting is designated by ‘‘T’’ in
    the model code.
    Note
    Light duty aluminum housings
    are intended for applications up
    to 210 bar (3000 psi) with light
    to moderate duty cycles.
    1
    B
    J
    A
    C
    H
    G
    D
    F
    E
    2
    3
    4
    K
    I
    B
    J
    A
    C
    H
    G
    D
    F
    E
    2
    3
    4
    K
    I
    (FDC*-**only)
    Note
    For C-10-4 housings for VCB
    valves see page J-25.
    Dimensions A B C D E F G H I J K Mass
    mm (inch) kg (lb)
    C-10-4 63,5 31,7 82,5 31,7 15,8 3,1 34,9 19,0 7,1 9,5 50,8 0,3
     (2.50) (1.25) (3.25) (1.25) (0.62) (0.12) (1.37) (0.75) (0.28) (0.37) (2.00) (0.72)
    C-16-4 106,6 50,8 133,3 50,8 25,4 3,8 53,9 25,4 8,7 22,2 82,5 1,4
     (4.00) (2.00) (5.25) (2.00) (1.00) (0.15) (2.12) (1.00) (0.34) (0.87) (3.25) (3.24)
    C-20-4 114,3 57,1 117,8 63,5 31,7 4,0 72,1 31,7 10,4 25,4 113,5 2,6
     (4.50) (2.25) (7.00) (2.50) (1.25) (0.16) (2.84) (1.25) (0.41) (1.00) (4.47) (5.76)
    C-**-4
    Aluminum housings
    (Light duty)
    .B
    J
    J-12.A EATON Screw-In Cartridge Valves E-VLSC-MC001-E1 September 2013
    Where measurements are critical request certified drawings. We reserve the right to change specifications without notice.
    Dimensions A B C D E F G H I J K Mass
    mm (inch) kg (lb)
    C-8-4 63,5 31,8 82,6 38,1 19,1 3,2 29,8 15,5 7,1 9,6 44,0 0,8
     (2.50) (1.25) (3.25) (1.50) (0.75) (0.13) (1.17) (0.61) (0.28) (0.38) (1.73) (1.76)
    C-10-4 76,2 38,1 88,9 50,8 25,4 9,5 36,6 20,8 7,1 12,7 52,5 0,9
     (3.00) (1.50) (3.50) (2.00) (1.00) (0.37) (1.44) (0.82) (0.28) (0.50) (2.07) (2.00)
    C-12-4 88,9 44,5 127,0 63,5 31,8 10,3 51,6 28,7 8,7 25,4 74,4 1,6
     (3.50) (1.75) (5.00) (2.50) (1.25) (0.40) (2.03) (1.13) (0.34) (1.00) (2.93) (3.6)
    C-16-4 114,3 60,3 139,7 63,5 31,8 10,3 57,0 28,4 8,7 25,4 85,5 2,4
     (4.50) (2.37) (5.50) (2.50) (1.25) (0.40) (2.24) (1.12) (0.34) (1.00) (3.37) (5.29)
    C-20-4 127,0 63,5 177,8 82,5 41,3 10,3 76,5 36,0 8,7 19,0 117,8 4,7
     (5.00) (2.50) (7.00) (3.25) (1.63) (0.40) (3.01) (1.42) (0.34) (0.75) (4.63) (10.5)
    B
    J
    A
    C
    H
    D
    F
    E
    1
    2
    3
    4
    I
    K
    G
    F
    B
    J
    A
    C
    H
    G
    D
    F
    E
    2
    3
    4
    I
    K
    ( DC*–** only)
     Ports 1, Part
    Housing 2, 3 & 4 Number Code
    C–8–4 1/4” BSPP 02–160747 (A)2G
     3/8” BSPP 02–160748 (A)3G
     SAE 4 02–160749 (A)4T
     SAE 6 02–160750 (A)6T
    C–10–4 1/4” BSPP 876709 (A)2G
     3/8” BSPP 876715 (A)3G
     SAE 6 876708 (A)6H
     SAE 8 876713 (A)8H
    C–12–4 3/4” BSPP 5986432-001 (A)6G
     SAE 10 5986434-001 (A)10T
     SAE 12 5986436-001 (A)12T
    C–16–4 1/2” BSPP 876728 (A)4G
     3/4” BSPP 876730 (A)6G
     SAE 10 876279 (A)10H
     SAE 12 876731 (A)12H
    C–20–4 3/4” BSPP 876744 (A)6G
     1” BSPP 876746 (A)8G
     SAE 12 876745 (A)12H
     SAE 16 876747 (A)16H
    Housing (FDC*-**only)
    C–10–4 1/4” BSPP 02–185804 (A)2G
     3/8” BSPP 02–185805 (A)3G
     SAE 6 02–185802 (A)6H
     SAE 8 02–185803 (A)8H
    Notes
    BSPP porting is designated by
    ‘‘G” in the model code SAE
    porting is designated by either
    “H” in the model code.
    Fatigue rated aluminum housings
    are intended for applications
    up to 210 bar (3000 psi)
    with harsh duty cycles. These
    housings have been fatigue
    rated to NFPA standards to one
    million cycles.
    For C-10-4 and C-12-4 housings
    for VCB valves see pages J-25
    & J-27 respectively.
    C-**-4
    Aluminum housings
    (NFPA fatigue rated)
    J
     EATON Screw-In Cartridge Valves E-VLSC-MC001-E1 September 2013 J-13.A
    Where measurements are critical request certified drawings. We reserve the right to change specifications without notice.
    Dimensions A B C D E F G H I J K L Mass
    mm (inch) kg (lb)
    C-8-4* 63,5 31,8 82,6 38,1 19,1 15,5 44,0 3,3 57,1 7,1 73,0 29,8 1,2
     (2.50) (1.25) (3.25) (1.50) (0.75) (0.61) (1.73) (0.13) (2.25) (0.28) (2.88) (1.17) (2.70)
    C-10-4 76,2 38,1 88,9 44,4 22,2 19,1 50,8 9,5 57,1 7,1 76,2 34,9 1,9
     (3.00) (1.50) (3.50) (1.75) (0.87) (0.75) (2.00) (0.37) (2.25) (0.28) (3.00) (1.37) (4.35)
    C-16-4 101,6 50,8 139,7 50,8 25,4 25,4 82,5 12,7 76,2 10,3 120,6 53,9 5,6
     (4.00) (2.00) (5.50) (2.00) (1.00) (1.00) (3.25) (0.50) (3.00) (0.40) (4.75) (2.12) (12.40)
    C-20-4 114,3 57,1 177,8 63,5 31,8 31,8 113,5 19,1 76,2 11,8 152,4 72,1 8,2
     (4.50) (2.25) (7.00) (2.50) (1.25) (1.25) (4.47) (0.75) (3.00) (0.47) (6.00) (2.84) (18.20)
    * 8 Series housings utilize slot instead of mounting holes.
     Ports 1, Part
    Housing 2, 3 & 4 Number Code
    C–8–4 1/4” BSPP 02–160751 (S)2G
     3/8” BSPP 02–160752 (S)3G
     SAE 4 02–160753 (S)4T
     SAE 6 02–160754 (S)6T
    C–10–4 1/4” BSPP 02–175139 (S)2G
     3/8” BSPP 02–175140 (S)3G
     SAE 6 02–175137 (S)6T
     SAE 8 02–175138 (S)8T
    C–16–4 1/2” BSPP 02–175143 (S)4G
     3/4” BSPP 02–175144 (S)6G
     SAE 10 02–175141 (S)10T
     SAE 12 02–175142 (S)12T
    C–20–4 1/2” BSPP 02–175147 (S)4G
     3/4” BSPP 02–175148 (S)6G
     SAE 12 02–175145 (S)12T
     SAE 16 02–175146 (S)16T
    Notes
    BSPP porting is designated by
    ‘‘G” in the model code SAE
    porting is designated by ‘‘T’’ in
    the model code 8 series utilize
    slot in place of mounting hole.
    Fatigue rated steel housings
    are intended for applications
    up to 350 bar (5000 psi) with
    harsh duty cycles. These housings
    have been fatigue rated to
    NFPA standards to one million
    cycles.
    For C-10-4 and C-12-4 housings
    for VCB valves see pages J-24
    & J-27 respectively.
    I
    B
    D
    E
    H
    J?
    K
    F
    G
    L
    1
    2
    3
    4
    A
    C
    C-**-4
    Steel housings
    (NFPA fatigue rated)
    J
    J-14.A EATON Screw-In Cartridge Valves E-VLSC-MC001-E1 September 2013
    Where measurements are critical request certified drawings. We reserve the right to change specifications without notice.
    Dimensions A B C D E F G H DIA. I J K L M N
    mm (inch)
    C-12-5S 100.8 50.4 113.5 50 25 12.3 34.1 54 8.7 76.1 25 50.4 88.5 16.7
     (3.97) (1.99) (4.47) (1.97) (0.99) (0.49) (1.34) (2.13) (0.34) (3.00) (0.99) (1.99) (3.49) (0.66)
    C-16-5S 113.5 56.8 126.2 62.7 31.4 9.5 36.1 58.7 8.7 85.7 31.4 56.8 104.8 16.9
     (4.47) (2.24) (4.97) (2.47) (1.24) (0.38) (1.42) (2.31) (0.34) (3.38) (1.24) (2.24) (4.13) (0.66)
    C-20-5S 126.2 63.1 138.9 75.4 37.7 12.7 37.6 62.3 10.3 87.4 37.7 63.1 114.3 16.8
     (4.97) (2.49) (5.47) (2.97) (1.49) (0.50) (1.48) (2.45) (0.40) (3.44) (1.09) (2.49) (4.50) (0.66)
     Aluminum Steel
     Ports Part Part
    Housing 2,3,4 Port 1,5 Number Code Number Code
    C–12–5S SAE 10 SAE 4 4998820-001 (A)10T 4998821-001 (S)10T
     SAE 12 SAE 4 4998820-002 (A)12T 4998821-002 (S)12T
     1/2” BSPP 1/4” BSPP 4998820-003 (A)04G 4998821-003 (S)04G
     3/4” BSPP 1/4” BSPP 4998820-004 (A)06G 4998821-004 (S)06G
    C–16–5S SAE 12 SAE 4 4994880-001 (A)12T 4994881-001 (S)12T
     SAE 16 SAE 4 4994880-002 (A)16T 4994881-002 (S)16T
     3/4” BSPP 1/4” BSPP 4994880-003 (A)06G 4994881-003 (S)06G
     1” BSPP 1/4” BSPP 4994880-004 (A)08G 4994881-004 (S)08G
    C–20–5S SAE 12 SAE 4 4998822-001 (A)12T 4998823-001 (S)12T
     SAE 16 SAE 4 4998822-002 (A)16T 4998823-002 (S)16T
     3/4” BSPP 1/4” BSPP 4998822-003 (A)06G 4998823-003 (S)06G
     1” BSPP 1/4” BSPP 4998822-004 (A)08G 4998823-004 (S)08G
    Notes
    BSPP porting is designated by
    ‘‘G” in the model code SAE porting
    is designated by ‘‘T’’ in the
    model code.
    Fatigue rated aluminum and steel
    housings are intended for applications
    up to 210 bar (3000 psi) and
    350 bar (5000 psi) respectively
    with harsh duty cycles. These
    housings have been fatigue rated
    to NFPA standards to one million
    cycles.
    D
    E
    B
    F
    ?I
    2
    4
    K
    L
    M
    A
    C
    J
    G
    3
    5
    H
    N
    C-**-5S
    Steel and aluminum housings
    (NFPA fatigue rated)
    .B
    J
     EATON Screw-In Cartridge Valves E-VLSC-MC001-E1 September 2013 J-15.A
    Where measurements are critical request certified drawings. We reserve the right to change specifications without notice.
     Minimum Minimum Full
    SAE Size Thread Size Spotface ? Thd Depth
    4 0.437”-20 UNF-2B 21,1 (0.82) 11,5 (0.45)
    6 0.563”-18 UNF-2B 24,7 (0.96) 12,7 (0.50)
    8 0.750”-16 UNF-2B 30,2 (1.18) 14,2 (0.56)
    10 0.875”-14 UNF-2B 34,2 (1.34) 16,6 (0.65)
    12 1.062”-12 UN-2B 41,3 (1.62) 19,0 (0.75)
    16 1.312”-12 UN-2B 48,6 (1.91) 19,0 (0.75)
     Minimum Minimum Full
    BSPP Thread Size Spotface ? Thd Depth
    1/4” 24 (0.94) 12,2 (0.48)
    3/8” 27 (1.06) 12,2 (0.48)
    1/2” 33 (1.29) 15,0 (0.59)
    3/4” 42 (1.65) 16,3 (0.64)
    1” 47 (1.85) 19,1 (0.75)
    Min. full
    thread depth
    Spotface ? 0,8 (0.03)
    Port Dimensions
    Key dimensions in all standard housings
    J
    J-30.A EATON Screw-In Cartridge Valves E-VLSC-MC001-E1 September 2013
    Where measurements are critical request certified drawings. We reserve the right to change specifications without notice.
    C-**-2 Cavity Plugs
    Size Assy. No. Seal Kit
    To fit Buna-N
    cavity A B C ?D Viton?
    C-4-2 0.4375’’-20 5,1 21.8 8,61/8,66 5986597-001 9900174-000
     (0.20) (0.86) (0.339/0.341) 9900175-000
    C-8-2 0.750’’-16 9,1 27.4 12,6/12,5 02-171585 02-165877
     (0.36) (1.08) (0.498/0.496) 02-165875
    C-10-2 0.875’’-14 7,9 31,7 15,8/15,7 565814 565806
     (0.31) (1.25) (0.62/0.62) 889627
    C-12-2 1.062’’-12 18,7 44,5 23,7/23,7 02-171710 02-165889
     (0.74) (1.75) (.936/.934) 02-165888
    C-16-2 1.312’’-12 12,7 44.7 28,5/28,5 565816 889631
     (0.50) (1.76) (1.12/1.12) 889635
    C-20-2 1.625’’-12 13,5 57,2 36,4/36,4 566440 889639
     (0.53) (2.25) (1.43/1.43) 889643
    Size Assy. No. Seal Kit
    To fit Buna-N
    cavity A B C D E Viton?
    C-4-3 0.4375’’-20 5,1 37,3 7,82/7,87 8,61/8,66 5986599-001 9900176-000
     (0.20) (1.47) (0.308/0.310) (0.339/0.341) 9900177-000
    C-8-3 0.750’’-16 9,1 40,7 14,2/14,0 15,8 02-171708 02-160755
     (0.36) (1.60) (0.56/0.55) (0.623/0.621) 02-160765
    C-10-3S 0.875’’-14 7,9 74,2 17,4/17,4 19,0/18,9 566436 02-173019
     (0.30) (1.86) (0.68/0.68) (0.74/0.74) 02-173020
    C-10-3 46,0 15,8/15,7 17,4/17,3 565815 889624
     (1.81) (0.62/0.62) (0.68/0.68) 889628
    C-12-3S 1.062’’-12 18,7 57,7 22,1/22, 1 23,7/23,7 02-171711 02-180095
     (0.74) (2.27) (0.874/0.872) (0.936/0.934) 02-165887
    C-12-3 67,1 – – 02-171712 02-165872
     (2.64) 02-165886
    C-16-3S 1.312’’-12 12,7 55,6 25,3/25,3 28,5/28,5 566438 889633
     (0.50) (2.18) (0.99/0.99) (1.2/1.2) 889637
    C-16-3 73,1 26,9/26,9 28,5/28,5 566437 889632
     (2,87) (1.06/1.06) (1.2/1.2) 889636
    C-20-3S 1.625’’-12 13,5 76.2 33,3/33,2 36,4/36,4 566442 02-113153
     (0.53) (3.0) (1.31/1.30) (1.43/1.43) 02-112969
    C-20-3 98.5 33,3/33,2 36,4/36,4 566441 889640
     (3.87) (1.31/1.30) (1.43/1.43) 889644
    D
    E
    1
    2
    3
    B
    A Thread
    C
    Note
    To block flow from
    between the ports in any
    unused standard cavity, in a
    housing or manifold. Order
    cavity plugs by part number.
    Note
    C-16-2 cavity plug can be
    used to block port 3 of
    C-16-3
    Standard Plugs
    C-**-3(S) Cavity Plugs
    Cavity Plugs
    .B
    J
     EATON Screw-In Cartridge Valves E-VLSC-MC001-E1 September 2013 J-31.A
    Where measurements are critical request certified drawings. We reserve the right to change specifications without notice.
    To Fit Assy
    Cavity Size A B C D ?E ?F ?G No.
    C-8-4 0.750’’-16 22,2 (0.87) hex. 8,6 54,6 12,6 14,2 15,8 02-171709
     Torque 35-40 (0.34) (2,15) (0.49) (0.55) (0.62)
     Nm(25-30 lbf ft)
    C-10-4(U) 0.875’’-14 25,4 (1.0) hex. 7,9 61,9 15,8/15,7 17,4/17,3 19,0/18,9 566244
     Torque 47-54 (0.31) (2.43) (0.62/0.62) (0.68/0.68) (0.74/0.74)
     Nm (35-40 lbf ft)
    C-16-4 1.312’’-12 38,1 (1.50) hex. 12,7 101.6 25,3/25,3 26,9/26,9 28,5/28,5 566443
     Torque 109-122 (0.50) (4.00) (0.99/0.99) (1.06/1.05) (1.12/1.12)
     Nm (80-90 lbf ft)
    C-20-4 1.625’’-12 47,6 (1.87) hex. 13,5 139,7 31,7/31,6 33,3/33,2 36,4/36,4 566443
     Torque 129-156 (0.53) (5.50) (1.24/1.24) (1.31/1.30) (1.43/1.43)
     Nm (95-115 lbf ft)
    C-**-4 Cavity Plugs
    IMPORTANT
    The cartridges
    listed are complete
    with seals compatible
    with antiwear hydraulic oil.
    If cartridges are to be compatible
    with antiwear
    and phosphate ester, order
    cartridges by part number
    plus the appropriate Viton
    seal kit as listed in Spare
    parts. Before using the
    cartridge, change the seals
    to Viton.
    ?
    D
    C
    2
    3
    4
    1
    B
    A
    Thread
    E
    F
    Special Purpose
    Cavity Plugs
    Functional Symbols
    To Fit Cavity Size Assy. No. Seal Kit
    C-10-2 02-186758 566806 (Buna-N)
     889627 (Viton?
    )
    Screen fitted on cartridge, intended direction of flow is from port 2 to 1 only. Maximum rated flow is
    76 L/min (20 USgpm), maximum operating pressure is 350 bar (5000 psi)
    To Fit Cavity Size Assy. No. Seal Kit
    C-8-3 02-186664 02-160755 (Buna-N)
     02-160756 (Viton?
    )
    C-10-3S 02-185257 02-173019 (Buna-N)
     02-173020 (Viton?
    )
    To Fit Cavity Size Assy. No. Seal Kit
    C-10-3 02-161831 889624 (Buna-N)
     889628 (Viton?
    )
    To Fit Cavity Size Assy. No. Seal Kit
    C-8-4 02-179151 02-160757 (Buna-N)
     02-160758 (Viton?
    )
    Filter cartridge plugs
    Special 3 way cavity plugs
    Special 4 way cavity plugs
    Cavity Plugs
    J
    J-40.A EATON Screw-In Cartridge Valves E-VLSC-MC001-E1 September 2013
    Where measurements are critical request certified drawings. We reserve the right to change specifications without notice.
    Features and Benefits
    ? Integrated disposable
    element which is
    screwed into the manifold
    port for last chance
    filtration
    ? Catches particles in a
    variety of sizes (20, 50,
    70 microns)
    ? Universally adaptable
    to all sizes of standard
    manifolds
    Filter and Element
    Model Code
    Sample model code
    ECF1SB1J3CB25
    Design?Specifications
    Rated flow 19 L/min (5 USgpm)
    Fluid compatibility Compatible with all petroleum, oil based and synthetic fluids.
     Not rated for use with fluoro-rubber or ethylene propylene seals.
    Temp range -30°C to +121°C (-22°F to 250°F)
    Pressure rating 10 bar (145 psi)
    Cavity BC20-S3
    Material Head Aluminum
     Bowl Aluminum
    Dry weight 0.11 kg (0.25 lbs)
    ECF 1 SB 1 J 3 C * **
    1 2 3 4 5 6 7 8 9
    1 Filter Series - ECF
    2 Element collapse rating
    1 – 250 PSI low collapse
    3 Port options
    SB – 1.312-12 UN SAE-16
    straight thread 1” O.D.
    tube
    4 Valve options
    1 – Non-Bypass
    (Screw directly into cavity)
    5 Indicator options
    J – No indicator
    6 Assembly length
    3 – 80.2mm (3.157”)
    7 Element construction
    C – Standard construction
    8 Seal material
    B – Buna-N
    V – Viton-A
    9 Fluid cleanliness
     Fluid Cleanliness Element
    Code Rating Construction
    15 20/18/15 C-Pak
    25 Wirescreen
    149 Wirescreen
    ECF - Pressure Filters
    Flows to 19 L/min (5 USgpm) ? Pressures to 207 bar (3000 psi)
    J
     EATON Screw-In Cartridge Valves E-VLSC-MC001-E1 September 2013 J-41.A
    Where measurements are critical request certified drawings. We reserve the right to change specifications without notice.
    3.157 2.634
    ?0.998
    1 5/16 - 12UN-2A IN.
    1.5
    HEX
    OUTLET
    ?0.75 P ilot Drill
    ?1.003±0.002
    ?1.234±0.002
在线询盘/留言
  • 免责声明:以上所展示的信息由企业自行提供,内容的真实性、准确性和合法性由发布企业负责,本网对此不承担任何保证责任。我们原则 上建议您选择本网高级会员或VIP会员。
    0571-87774297