净重 (Kg) | 0.159 Kg |
产品尺寸 (W x L X H) | 未提供 |
包装尺寸 | 9.10 x 10.90 x 5.80 |
包装尺寸单位的测量 | CM |
数量单位 | 1 件 |
包装数量 | 1 |
其他产品信息 | |
EAN | 6940408102101 |
UPC | 887621424480 |
商品代码 | 85176200 |
LKZ_FDB/ CatalogID | ST72 |
产品组 | 4510 |
原产国 | 中国 |
Compliance with the substance restrictions according to RoHS directive | RoHS 合规开始日期: 2013.08.30 |
以下S7-200 224XP CPU移植举例来看,如何从硬件配置到软件编程的移植
移植举例,如下表所示:
表6. S7-200 移植到 S7-200 SMART 对照表
类型 | S7-200 | S7-200 SMART |
---|---|---|
CPU | 224XP:6ES7 214-2AD23-0XB8 | ST30:6ES7 288-1ST30-0AA0 |
供电电源 | DC 24V | DC 24V |
程序存储器 | 16 KB | 18 KB |
用户存储器(V区) | 10 KB | 12 KB |
集成DI/DO |
DI:14/DO:10 |
DI:18/DO12 |
扩展DI/DO | EM223:6ES7 223-1BH22-0XA0 DI:8/DO:8 | EM DT16:6ES7 288-2DT16-0AA0 DI:8/DO:8 |
DI/DO通道总数 | DI:24/DO:18 | DI:26/DO:20 |
集成AI/AO | AI:2(±10 V)/AO:1 |
EM AE04:6ES7 288-3AE04-0AA0 AI:4 |
扩展AI/AO | EM235:6ES7 235-0KD22-0XA8 AI:4/AO:1 | EM AM06:6ES7 288-3AM06-0AA0 AI:4/AO:2 |
AI/AO通道总数 | AI:6/AO:2 | AI:8/AO:2 |
热电偶 (TC) | EM231:6ES7 231-7PD22-0XA8 4*TC | EM AT04:6ES7 288-3AT04-0AA0 4*TC |
热电阻 (RTD) | EM231:6ES7 231-7PB22-0XA8 2*RTD | EM AR02:6ES7 288-3AR02-0AA0 2*RTD |
以太网口 | CP243-1:6GK7 243-1EX01-0XE0 | 集成 |
RS485通讯口 | 集成:2个 | 集成:1个+CB CM01:6ES7 288-5CM01-0AA0 |
DP 从站通讯 | EM277:6ES7 277-0AA22-0XA0 | DP01:6ES7 288-7PD01-0AA0 |
模块总数 | 6 | 6+1 |
注意:以上表格仅用于举例说明 S7-200 移植到S7-200 SMART着重点,非工程实际应用
以下为S7-200 安装组态步骤: 代理西门子全新1200通讯模块6ES7241-1CH32-0XB0
步骤1:安装
图3. S7-200安装方式
步骤2:AI 模块拨码设置
表7. EM235 拨码设置
单极性 | 满量程输入 | 分辨率 | |||||
---|---|---|---|---|---|---|---|
SW1 |
SW2 |
SW3 |
SW4 |
SW5 |
SW6 |
||
ON | OFF | OFF | ON | OFF | ON | 0 - 50 mV | 12.5μV |
OFF | ON | OFF | ON | OFF | ON | 0 - 100 mV | 25μV |
ON | OFF | OFF | OFF | ON | ON | 0 - 500 mV | 125μV |
OFF | ON | OFF | OFF | ON | ON | 0 - 1 V | 250μV |
ON | OFF | OFF | OFF | OFF | ON | 0 - 5 V | 1.25mV |
0 - 20 mA | 5μA | ||||||
OFF | ON | OFF | OFF | OFF | ON | 0 - 10 V | 2.5mV |
双极性 | 满量程输入 | 分辨率 | |||||
SW1 | SW2 | SW3 | SW4 | SW5 | SW6 | ||
ON | OFF | OFF | ON | OFF | OFF | ±25 mV | 12.5μV |
OFF | ON | OFF | ON | OFF | OFF | ±50 mV | 25μV |
OFF | OFF | ON | ON | OFF | OFF | ±100 mV | 50μV |
ON | OFF | OFF | OFF | ON | OFF | ±250 mV | 125μV |
OFF | ON | OFF | OFF | ON | OFF | ±500 mV | 250μV |
OFF | OFF | ON | OFF | ON | OFF | ±1 V | 500μV |
ON | OFF | OFF | OFF | OFF | OFF | ±2.5 V | 1.25mV |
OFF | ON | OFF | OFF | OFF | OFF | ±5 V | 2.5 mV |
OFF | OFF | ON | OFF | OFF | OFF | ±10 V | 5 mV |
表8. EM231 2*RTD模块拨码
RTD Type and Alpha¹ |
SW1 |
SW2 |
SW3 |
SW4 |
SW5 |
RTD Type and Alpha¹ |
SW1 |
SW2 |
SW3 |
SW4 |
SW5 |
100Ω Pt 0.003850 |
0 |
0 |
0 |
0 |
0 |
100Ω Pt 0.003902 |
1 |
0 |
0 |
0 |
0 |
200Ω Pt 0.003850 |
0 |
0 |
0 |
0 |
1 |
200Ω Pt 0.003902 |
1 |
0 |
0 |
0 |
1 |
500Ω Pt 0.003850 |
0 |
0 |
0 |
1 |
0 |
500Ω Pt 0.003902 |
1 |
0 |
0 |
1 |
0 |
1000Ω Pt 0.003850 |
0 |
0 |
0 |
1 |
1 |
1000Ω Pt 0.003902 |
1 |
0 |
0 |
1 |
1 |
100Ω Pt 0.003920 |
0 |
0 |
1 |
0 |
0 |
SPARE |
1 |
0 |
1 |
0 |
0 |
200Ω Pt 0.003920 |
0 |
0 |
1 |
0 |
1 |
100Ω Ni 0.00672 |
1 |
0 |
1 |
0 |
1 |
500Ω Pt 0.003920 |
0 |
0 |
1 |
1 |
0 |
120Ω Ni 0.00672 |
1 |
0 |
1 |
1 |
0 |
1000Ω Pt 0.003920 |
0 |
0 |
1 |
1 |
1 |
1000Ω Ni 0.00672 |
1 |
0 |
1 |
1 |
1 |
100Ω Pt 0.00385055 |
0 |
1 |
0 |
0 |
0 |
100Ω Ni 0.006178 |
1 |
1 |
0 |
0 |
0 |
200Ω Pt 0.00385055 |
0 |
1 |
0 |
0 |
1 |
120Ω Ni 0.006178 |
1 |
1 |
0 |
0 |
1 |
500Ω Pt 0.00385055 |
0 |
1 |
0 |
1 |
0 |
1000Ω Ni 0.006178 |
1 |
1 |
0 |
1 |
0 |
1000Ω Pt 0.00385055 |
0 |
1 |
0 |
1 |
1 |
10000Ω Pt 0.003850 |
1 |
1 |
0 |
1 |
1 |
100Ω Pt 0.003916 |
0 |
1 |
1 |
0 |
0 |
10Ω Cu 0.004270 |
1 |
1 |
1 |
0 |
0 |
200Ω Pt 0.003916 |
0 |
1 |
1 |
0 |
1 |
150Ω FS Resistance |
1 |
1 |
1 |
0 |
1 |
500Ω Pt 0.003916 |
0 |
1 |
1 |
1 |
0 |
300Ω FS Resistance |
1 |
1 |
1 |
1 |
0 |
1000Ω Pt 0.003916 |
0 |
1 |
1 |
1 |
1 |
600Ω FS Resistance |
1 |
1 |
1 |
1 |
1 |
图4. EM231 RTD 模块拨码设置
图5. EM231 TC 模块拨码设置
步骤3:寻址
方式1:S7-200 的地址连续,可按照模块的安装次序分配地址
方式2:可通过查看菜单“PLC”>“信息” 查看模块起始地址,如下图所示:
图6. S7-200 PLC 信息
以下为S7-200 SMART 安装组态步骤:
步骤1:安装
图7. S7-200 SMART 安装步骤 代理西门子全新1200通讯模块6ES7241-1CH32-0XB0
步骤2:硬件组态及寻址
图8. S7-200 SMART 模块组态
步骤3:模块设置
使用 IO-Link K20 模块,可从控制柜外收集多达 8 个二线制传感器,并通过三线制接口将其与 IO-Link 端口连接。这样,不仅显著降低了接线费用,而且还节省了控制柜空间。
IO-Link K20 模块特别适合此类应用:先前采用无源传感器分配盒连接二线制传感器。从而避免了使用无源分配器及繁琐的、易于出错的接线。
通过 IO-Link 连接二线制传感器和控制装置,降低了成本
针对二线制传感器使用参数(如可参数化常开/常闭触点和输入继电器)
不使用无源分配器,减少了接线工作,使接线故障降至最低
还可选择传输诊断消息(如传感器供电过载)
可在苛刻的环境条件下使用(防护等级 IP67)
使用 IO-Link K20 模块,一方面将 IO-Link 从单纯的点到点接口进行了扩展,另一方面还创建了分布式结构。必须注意的是:受 IO-Link 连接电缆长度限制,IO-Link 模块与主站之间的距离不得超过 20m。
对于二线制传感器连接,提供有两种型号的 IO-Link K20 模块:4 路数字量输入型和 8 路数字量输入型。传感器连接采用 M8 或 M12 接口,且通过 M12 标准连接线路与 IO-Link 主站建立连接。
应用 代理西门子全新1200通讯模块6ES7241-1CH32-0XB0
在所有生产自动化现场连接二线制传感器
使用 IO-Link K20 模块更换传感器分配盒