Model NO.
(N)TSCGECECWÖ U
Material Shape
Round Wire
Range of Application
Cold-Resistant
Certification
ISO9001, CE, CCC, RoHS, VDE
Standard
VDE0250 Part 812
Operating Temperature
-40 Degree to 80 Degree
Transport Package
500m 1000m Per Drum
(N)TSCGECECWÖU
8.7/15kV and 12/20kV Cable
APPLICATIONFlexible cable suitable for reeling drums of tunnel boring
machines and generally for tunnel applications. Suitable for
indoor and outdoor applications.Cable specificationPhase Conductor
Class 5 tinned copper conductor according to VDE 0295
(IEC 60228)
Insulation
Rubber compound Type 3GI3 according to VDE 0207 Part 20
Semi-Conductive Layers
Semi-conductive tape over the conductor and inner and outer
semi-conductive rubber layer on the insulation
Protective Earth Conductor
Individual copper wire screen
Control Conductor
Class 5 tinned copper conductor according to VDE 0295
(IEC 60228)
Central Filler
Semi-conductive compound on a textile polyester support
Inner Sheath
Rubber compound Type 5GM5 according to VDE 0207 Part 21
Monitoring Conductor
Copper wire screen over the inner sheath
Outer Sheath
Rubber compound Type 5GM5 according to VDE 0207 Part 21
CHARACTERISTICSVoltage Rating (Uo/U)
8.7/15kV
12/20kV
Test Voltage
8.7/15kV: 24kV
12/20kV: 29kV
Maximum Short Circuit Temperature
+250°C
Ambient Temperature
Fixed: -40°C to +80°C
Flexed: -25°C to +80°C
Minimum Bending Radius
Fixed: 6 x overall diameter
Flexed: 10 x overall diameter
Maximum Torsional Stress
±25°/m
Maximum Tensile Load*
15N/mm2
Sheath Colour
Red
CERTIFICATE
PRODUCTION LINE AND TEST EQUIPMENTPACKAGE