产品简介
美国Gammex Sono404超声模体
美国Gammex Sono404超声模体
产品价格:¥100
上架日期:2019-03-20 15:49:20
产地:美国
发货地:深圳
供应数量:不限
最少起订:1个
浏览量:495
资料下载:暂无资料下载
其他下载:暂无相关下载
详细说明

    Gammex Sono404小范围模体,Gammex Sono404超声质量模体


    Gammex Sono404小范围模体,Gammex Sono404超声质量模体
    在血管和心脏超声波中提高QC测量的准确性。
    对最困难的情况进行有效的测试和培训
    确保所有传感器和系统设置均在2至18 MHZ的整个临床频率范围内通过HE(高等效)Gel™专利测试
    定期测试您的高频传感器,以确保准确的患者测量


    Gammex Sono404小范围模体,Gammex Sono404超声质量模体今天在世界各地的乳房护理中心和超声诊断部门使用。
    他们继续广泛采用的原因是与超声成像技术的发展保持同步,以测量小部件和腔内超声系统的图像质量。

    Gammex Sono404小范围模体,Gammex Sono404超声模体

    Gammex Sono404小范围模体,Gammex Sono404超声模体

    Gammex Sono404小范围模体,Gammex Sono404超声模体

    Gammex Sono404小范围模体,Gammex Sono404超声质量模体:
    支持符合ACR,AIUM,ESTRO和其他质量保证计划的要求
    与医学物理学家一起设计,并包括密集的针脚目标,是测试高频换能器的理想选择
    具有耐用可靠的HE Gel,具有近似线性响应的衰减,频率在2到18 MHz之间
    提供频率超过8 MHz的衰减响应,以支持代表人体组织的精确轴向分辨率和穿透深度

    Gammex Sono404小范围模体,Gammex Sono404超声质量模体
    主要用于满足血管和心脏超声波应用的特殊需求
    特点紧密间距针目标,测试高频率传感器的理想选择
    包括HE凝胶,可以复兴,以便您的幻像可以重新验证,以加强您的投资
    支持符合ACR,AIUM,ESTRO和其他质量保证计划的要求

     

    衰减系数3 0.5或0.7dB / cm / MHz
    频率衰减的变化1,4 在0.7dB / cm / MHz下0.5dB / cm / MHz 
    f1.1的f1.08
    HE凝胶凝固点: <0 ° C
    HE凝胶熔点: > 100 ° Ç
    频率范围2 2 - 18 MHz
    声音的速度: 1540米/秒
    消声囊肿: 10个囊,直径1,2,3和7毫米
    灰度目标: 3个目标,-6,+ 6和+12 dB,
    水平几何组: 直径7毫米
    垂直几何目标: 3组,在1,3.5和6厘米深
    水平几何目标: 17针,直径0.1毫米,深度1至9厘米,间隔5毫米
    死区检测(交叉目标): 12针,1毫米直径0.1毫米,10毫米间距1厘米深5厘米
    特征   Sono404 SCG Sono404 SC
    组织模仿材料,获得专利的多频HE Gel   
    扫描表面,专利复合膜:  
    统一评估:  
    几何评估:  
    灵敏度评估:  
    决议评估:  
    渗透深度:  
    死区检测:  
    谐波成像:  
    消声囊肿:  
    灰度目标:    

    Sono404™ Phantoms
    Enhance the accuracy of your QC measurements in vascular and cardiology ultrasounds.
    Efficiently test and train for the most difficult cases
    Ensure all transducers and system settings are fully tested across the entire clinical frequency range from 2 to 18 MHZ with patented HE (High Equivalency) Gel™
    Test your high frequency transducers routinely to ensure accurate patient measurements

    Sono404 Phantoms are in use today in breast care centers and diagnostic ultrasound departments around the world.
    Their continued widespread adoption is attributed to a design that keeps pace with advancing ultrasound imaging technologies for measuring image quality of small parts and intra-cavity ultrasound systems.

    Sono404 Phantoms:
    Support compliance with ACR, AIUM, ESTRO and other QA program requirements
    Have been designed with medical physicists, and include closely spaced pin targets, ideal for testing high frequency transducers
    Feature durable and reliable HE Gel, with a near-linear-response of attenuation with with frequencies between 2 and 18 MHz
    Offer response of attenuation with frequencies over 8 MHz to support accurate axial resolution and penetration depth representative of human tissue
     

    Gammex Sono404小范围模体,Gammex Sono404超声模体

    Gammex Sono404小范围模体,Gammex Sono404超声模体

    Gammex Sono404小范围模体,Gammex Sono404超声模体

     

    Gammex Sono模体选型表:

    功能

    Sono403 SCG

    多功能

     

    Sono410 SCG

    Full Contact™

    Sono408

    球形病灶

    Sono404 SCG

    微小部位

    声速 1540 m/s

    频率范围2-18 MHz

    专利型复合薄膜扫描表面

    线 针靶 垂直

    20mm(深2至16cm)

    1、2和4cm(深1至15cm)

     

    5mm(深1至9cm)

     

    线 针靶 水平

    30mm(深2至12cm)

    2cm(深2cm)、4cm

    (深7到13cm)

     

    10mm(深1和5cm)

    消声囊肿(mm)

    直径2、4、6、10mm

    12个标靶,直径 1、2、4、8mm

     

    直径1、2、4、7mm

    灰度(dB)

    3个标靶,直径10mm,

    -6、+6 和 +12

    6个标靶,直径8mm,-6、+6 和 +12

     

    3个标靶,直径7mm,-6、+6 和+12

    Full Contact™ 弧形扫描表

     

       

    消声球形病灶

       

    211个4mm直径病灶,垂直间距0.5cm,水平间距0.75cm;105个2 mm直径病灶,垂直与水平间距均0.5cm

     

    可提供重新验证报告

    超越ACR和其他协会要求

     

在线询盘/留言
  • 免责声明:以上所展示的信息由企业自行提供,内容的真实性、准确性和合法性由发布企业负责,本网对此不承担任何保证责任。我们原则 上建议您选择本网高级会员或VIP会员。
    0571-87774297