PP系列用于双坐标测量
Model |
Accuracy grade |
Substrate and mounting |
Interpolations error |
Measuring length |
± 2 μm |
Glass grid plate, |
± 12 nm |
Measuring range 68x68mm |
PP 281
|
PP 281 R |
Measuring standard Coefficient of linear expansion |
Two-coordinate TITANID phase grating on glass; grating period 8 µm αtherm 8 · 10–6 K–1 |
Accuracy grade |
±2 µm |
Measuring range |
68 mm x 68 mm, other measuring ranges upon request |
Reference marks1) |
One reference mark in each axis, 3 mm after beginning of measuring length |
Interface |
1 VPP |
Signal period |
4 µm |
Cutoff frequency –3 dB |
≥ 300 kHz |
Traversing speed |
≤ 72 m/min |
Interpolation error Position noise RMS |
±12 nm 2 nm (450 kHz)2) |
Electrical connection |
0.5 m cable with 15-pin D-sub connector (male); interface electronics in the connector |
Cable length |
See interface debion, but ≤ 30 m (with HEIDENHAIN cable) |
Voltage supply |
DC 5 V ±0.25 V |
Current consumption |
< 185 mA per axis |
Vibration 55 Hz to 2000 Hz Shock 11 ms |
≤ 80 m/s2 (EN 60 068-2-6) ≤ 100 m/s2 (EN 60 068-2-27) |
Operating temperature |
0 °C to 50 °C |
Mass Scanning head Grid plate Connecting cable Connector |
170 g (without cable) 75 g 37 g/m 140 g |
1) The reference mark signal deviates in its zero crossovers from the interface specification (see Mounting Instructions) 2) With –3 dB cutoff frequency of the subsequent electronics |