一、节能型轴流通风机SF-6-4/2.2KW适用范围:
1、爆炸性气体混合物危险场所:1区、2区。
2、爆炸性气体混合物:ⅡA、ⅡB。
3、温度组别:T1~T4。
4、防爆标志: ExdⅡBT4。
二、节能型轴流通风机SF-6-4/2.2KW型号含义:
三、节能型轴流通风机SF-6-4/2.2KW主要技术参数:
机号No. |
叶轮直径mm |
转速r/min |
风量(立方米/h) |
全压pa |
配用电机功率(kw) |
2.8 |
280 |
2900 |
1506-3059 |
143.0-216.7 |
0.12/0.18/0.25/0.37 |
1450 |
753-1529 |
35.7-54.1 |
0.025/0.04 |
||
3.15 |
315 |
2900 |
2144-4356 |
181-274.3 |
0.18/0.25/0.37/0.55 |
1450 |
1072-2178 |
45.2-68.5 |
0.025/0.04/0.06/0.09 |
||
3.55 |
355 |
2900 |
3069-6235 |
230.0-348.4 |
0.37/0.55/0.75/1.1 |
1450 |
1534-3117 |
57.5-87.1 |
0.04/0.06/0.09/0.12 |
||
4 |
400 |
2900 |
4391-8920 |
292.0-442.4 |
0.55/1.1/1.5/2.2 |
1450 |
2195-4460 |
73.0-110.6 |
0.09/0.12/0.18/1.25 |
||
4.5 |
450 |
1450 |
3126-6350 |
92.3-139.9 |
0.18/0.25/1.37/0.55 |
5 |
500 |
1450 |
4288-8711 |
114.0-172.8 |
0.25/0.37/0.55/0.75 |
2900 |
2839-5765 |
49.9-75.7 |
0.37 |
||
5.6 |
560 |
1450 |
6025-12239 |
143.0-216.7 |
o.37/0.55/0.75/1.1/1.5 |
960 |
3989-8190 |
62.7-95.0 |
0.37 |
||
6.3 |
630 |
1450 |
8579-17426 |
181.0-274.3 |
0.75/1.1/1.5/2.2 |
960 |
5879-11537 |
79.3-120.2 |
0.37/0.75 |
||
7.1 |
710 |
1450 |
12279-24943 |
230.0-348.4 |
1.5/2.2/3/4 |
960 |
8130-16514 |
108.0-152.7 |
0.75/1.1 |
||
8 |
800 |
1450 |
17566-35682 |
292.0-442.4 |
2.2/4/5.5/7.5 |
960 |
11630-23624 |
127.9-193.9 |
0.75/1.1/1.5/2.2 |
||
9 |
900 |
960 |
16559-33636 |
162.9-245.4 |
1.5/2.2/3/4 |
10 |
1000 |
960 |
22715-46141 |
199.9-303.0 |
2.2/3/4/7.5 |
11.2 |
1120 |
960 |
31913-64824 |
250.8-380.1 |
4/5.5/7.5/11 |
产品型号 |
风量m3/h |
静压Pa |
电压V |
频率Hz |
功率W |
电流A |
转速rpm |
电容μF |
WEXD-250D4 |
1700 |
50 |
380 |
50 |
60 |
0.15 |
1420 |
— |
WEXD-250E4 |
1500 |
50 |
220 |
50 |
60 |
0.25 |
1350 |
2 |
WEXD-300D4 |
1800 |
50 |
380 |
50 |
80 |
0.20 |
1400 |
— |
WEXD-300E4 |
1600 |
50 |
220 |
50 |
80 |
0.37 |
1380 |
3 |
WEXD-350D4 |
2800 |
50 |
380 |
50 |
125 |
0.35 |
1380 |
— |
WEXD-350E4 |
2200 |
50 |
220 |
50 |
125 |
0.53 |
1360 |
4 |
WEXD-400D4 |
3800 |
45 |
380 |
50 |
180 |
0.40 |
1400 |
— |
WEXD-400E4 |
3600 |
50 |
220 |
50 |
180 |
0.8 |
1400 |
6 |
WEXD-450D4 |
6500 |
50 |
380 |
50 |
250 |
0.52 |
1350 |
— |
WEXD-450E4 |
6300 |
50 |
220 |
50 |
250 |
1.15 |
1360 |
8 |
WEXD-500D4 |
7800 |
50 |
380 |
50 |
370 |
0.7 |
1350 |
— |
WEXD-500E4 |
7600 |
50 |
220 |
50 |
370 |
1.75 |
1200 |
12 |
WEXD-550D4 |
9300 |
50 |
380 |
50 |
550 |
1.2 |
1300 |
— |
WEXD-550E4 |
8300 |
50 |
220 |
50 |
550 |
2.1 |
1180 |
10 |
WEXD-600D4 |
12500 |
100 |
380 |
50 |
750 |
1.6 |
1380 |
— |
WEXD-650D4 |
16500 |
100 |
380 |
50 |
1900 |
3.5 |
1350 |
— |
WEXD-700D6 |
13000 |
50 |
380 |
50 |
1000 |
2.3 |
920 |
— |
WEXD-750D6 |
16200 |
50 |
380 |
50 |
1200 |
3.2 |
910 |
— |
WEXD-800D6 |
23000 |
75 |
380 |
50 |
1400 |
3.4 |
940 |
— |
WEXD-900D6 |
25000 |
75 |
380 |
50 |
1600 |
3.2 |
940 |
— |
四、节能型轴流通风机SF-6-4/2.2KW产品特点:
1、防爆轴流风机由防爆电机、叶片、风筒等部件组成。
2、噪音低、能耗低、防爆性能可靠。
3、电缆布线。
4、主轴转速(或电机功率或风量)可根据用户要求选配。
五、节能型轴流通风机SF-6-4/2.2KW安装说明:
1、安装前应详细检查风机是否有损坏变形,如有损坏变形,待修理妥善后,方可进行安装。
2、安装时要注意检查各不如部分有无松动,叶片与风筒间隙应均匀,不得相碰。
3、连接风口管道的重量不应由风机的风筒承受,安装时应另加支撑。
4、在风机风口端必须装集风器,并安装防护网。
5、风机底座必须与地基平面自然接合,不得敲打底座强制联接,以防底座变形,安装时应校正机座,加
垫铁片、保持水平位置,然后拧紧地脚螺栓。
6、安装完毕后,必须先进行实验,待运行正常后,才允许正式使用。
六、节能型轴流通风机SF-6-4/2.2KW安装方式可分为以下四种:
1、壁式:风扇外形两端一边是喇叭口型,一边是90度直角法兰型。
2、管道式:风扇两端都成直角法兰边可以安装在管道的中间。
3、岗位式:除具有壁式特征外,附加岗位脚架附件,风扇腰中打安装孔Φ 12.
4、固定式:除具有壁式特征外,底部焊接固定安装架(40x40角铁制)。
节能型轴流通风机SF-6-4/2.2KW,主要被安装在墙上或房顶上作为室内通风设备,风机采用防爆定量,铝风叶,因此具有良好的防爆性能,能够适用于易燃易爆场所。
【温馨提示】:天网防爆销售热线:15958788721 (王经理)
由于篇幅限制原因,如果您对产品的价格、厂家、型号、图片有什么疑问,请联系我们获取该产品的信息。