|
|||||||||||
型号 |
S-350-5 |
S-350-7.5 |
S-350-12 |
S-350-13.5 |
S-350-15 |
S-350-24 |
S-350-27 |
S-350-48 |
|||
输出 |
直流输出电压 |
5V |
7.5V |
12V |
13.5V |
15V |
24V |
27V |
48V |
||
输出电压容差(注3) |
±2% |
±2% |
±1% |
±1% |
±1% |
±1% |
±1% |
±1% |
|||
额定输出电流(注4) |
50A |
40A |
29A |
25.8A |
23.2A |
14.6A |
13A |
7.3A |
|||
输出电流范围 |
0-50A |
0-40A |
0-29A |
0-25.8A |
0-23.2A |
0-14.6A |
0-13A |
0-7.3A |
|||
输出功率 |
250W |
300W |
348W |
348.3W |
348W |
350.4W |
351W |
350.4W |
|||
纹波及噪音(注2) |
150mVp-p |
150mVp-p |
150mVp-p |
150mVp-p |
150mVp-p |
150mVp-p |
200mVp-p |
240mVp-p |
|||
直流电压可调范围 |
-10%,+12% |
±20% |
-16%,+10% |
-12%,+11% |
-10%,+20% |
-16%,+10% |
-4%,+18% |
-15%,+17% |
|||
启动、上升、保持时间 |
200ms,50ms,20ms满载 |
||||||||||
输入 |
输入电压范围 |
90~132 VAC/180~264VAC 47~63 Hz;由开关选择254~370VDC |
|||||||||
交流输入电流 |
6.5A/115 V 4A/ 230 V |
||||||||||
效率 |
74% |
76% |
76% |
79% |
78% |
81% |
82% |
83% |
|||
冲击电流 |
冷启动电流50A/115V 50A/230V |
||||||||||
漏电流 |
<3.5 mA/240VAC |
||||||||||
保护特性 |
过载保护 |
105%~135% |
|||||||||
保护方式:电流限制 ,自动恢复 |
|||||||||||
过电压保护 |
115%~135% |
||||||||||
保护方式:电压限制 ,自动恢复 |
|||||||||||
风机开/关控制 |
RT3≥55℃风机开,≤45℃风机关,≥80℃切断输出 (5~7.5V) |
||||||||||
RT3≥65℃风机开,≤55℃风机关,≥80℃切断输出 (12~15V) |
|||||||||||
RT3≥70℃风机开,≤60℃风机关,≥85℃切断输出 (24~48V) |
|||||||||||
环境 |
工作温度、湿度 |
-10℃~+60℃;20%~90 %RH |
|||||||||
保存温度、湿度 |
-20℃~+85℃;10%~95 %RH |
||||||||||
抗震性 |
10~500Hz,2G 10min./1周期,时长60分钟,各轴 |
||||||||||
安全 |
耐压性 |
输入输出间:1.5KVAC 输入与地:1.5KVAC 输出与地:0.5KVAC |
|||||||||
绝缘电阻 |
输入输出间,输入与地,输出与地: 100M Ohms/500VDC |
||||||||||
符合标准 |
安全标准 |
符合UL1950 |
|||||||||
EMC标准 |
Drsign refer to FCC Part15 J Conduction Class A |
||||||||||
其它 |
重量 |
1.1.5Kg |
|||||||||
包装 |
12pcs/14.3Kg/0.93CUFT |
||||||||||
备注 |
|