产品简介
西门子NCU573.2
西门子NCU573.2
产品价格:¥22
上架日期:2012-04-09 09:47:50
产地:德国
发货地:上海
供应数量:不限
最少起订:1台
浏览量:439
资料下载:暂无资料下载
其他下载:暂无相关下载
详细说明

    西门子NCU573.2
    NCU  573.5/573.4/573.3/573.2/572.5/572.4/572.3/572.2/571.5/561.5/571.4/571.3/571.2

    上海启水自动化科技有限公司(西门子核心分销商)

     联系人 :李 松( 销售经理 24小时服务热线 186 0165 7819

     电话( Tel ): 021-60641328    

    工作( Q Q  1471187088 邮箱( Email )::1471187088@qq.com  

     地址( Add ):上海市松江区弘翔路58195

    公司优势产品系列=西门子S7-200CN | S7-300PLC |  触摸屏 | 变频器 | 伺服电机 | 数控系统 | 总线电缆| 开关电源

     
    SINUMERIK 840D/DE BOX FOR ELECTRONIC CONTROL DEVICE NCU BOX FOR INSTALLATION OF NCU 561.2/.3/.4/.5 NCU 571/571.2/.3/.4/.5 NCU 572/572.2/.3/.4/.5 NCU 573.2/.3/.4/.5 WITH POWER UNIT, BATTERY AND FAN

    Technical specifications

    Order No.

    6FC5356-0BB15-0AA0

    6FC5357-0BB15-0AA0

    6FC5357-0BB25-0AA0

    6FC5357-0BB35-0AA0

    Product name

    SINUMERIK 840D powerline NCU 561.5

    SINUMERIK 840D powerline NCU 571.5

    SINUMERIK 840D powerline NCU 572.5

    SINUMERIK 840D powerline NCU 573.5

    Processor

    Celeron

     

     

    Pentium III

    SIMATIC S7 - integrated

    PLC 317-2 DP

    Input voltage

    Via SIMODRIVE device bus

    Degree of protection according to EN 60529 (IEC 60529)

    IP20 (with NCU box)

    Humidity rating in accordance with EN 60721-3-3

    Class 3K5 condensation and icing excluded. Low air temperature 0 °C (32 °F).

    Relative humidity

     

     

     

     

    • Storage

    10 ... 95 %

     

     

     

    • Transport

    10 ... 95 %

     

     

     

    • Operation

    < 95% for 1h, annual average < 65%

    Ambient temperature

     

     

     

     

    • Storage

    -20 … +60 °C (-4 ... +140 °F)

     

     

     

    • Transport

    -20 … +60 °C (-4 ... +140 °F)

     

     

     

    • Operation

    0 … 55 °C (32 ... 131 °F)

     

     

     

    Dimensions

     

     

     

     

    • Width

    50 mm (1.97 in)

     

     

     

    • Height

    316 mm (12.4 in)

     

     

     

    • Depth

    207 mm (8.15 in)

     

     

     

    Weight,approx.

    0.72 kg (1.59 lb)

     

     

    1.05 kg (2.32 lb)

    Approvals

    CE, cULus

     

     

     


    Ordering data:
      

    Release (only as spare part)
    (product status: Cancellation/discontinuation):

    6FC5357-0BB23-0AA0


    (predecessor:
    6FC5357-0BB22-0AE0)

    SINUMERIK 840DE
    NCU 572.3, 400 MHZ, 64 MB
    WITHOUT SYSTEM SOFTWARE
    MEMORY: NC 0.5MB, PLC 96KB
    PROFIBUS-DP PREPARED
    ACCORDING TO IEC 61508

    6FC5357-0BB33-0AA0


    (predecessor:
    6FC5357-0BB33-0AE3)

    SINUMERIK 840D/DE
    NCU 573.3, 650 MHZ, 64 MB
    WITHOUT SYSTEM SOFTWARE
    MEMORY: NC 2.5MB, PLC 96KB
    PROFIBUS-DP PREPARED
    ACCORDING TO IEC 61508



    NCU system software, compatibility:

      Hardware

    NCU system software, compatibility subsequently tested

      NCU 572.3

     

    6FC5357-0BB22-0AE0

       12-axis software:
      6FC520-_BY30-_AH_
      6FC520-_BX30-_AH_

      SW4.4 from V04.04.38
      SW5.3 from V05.03.08
      all SW6.x

    6FC5357-0BB23-0AA0

      SW4.4 from V04.04.39
      SW5.3 from V05.03.42
      all SW6.x

      NCU 573.3

     

     

    6FC5357-0BB33-0AE2

      12-axis software:  
      6FC520-_BY30-_AH_
      6FC520-_BX30-_AH_

      31-axis software:
      6FC520-_AY30-_AH_
      6FC520-_AX30-_AH_

       all SW4.x
      all SW5.x
      all SW6.x
      all SW7.x

    6FC5357-0BB33-0AE3

      SW4.4 from V04.04.39
      SW5.3 from V05.03.18
      all SW6.x
      all SW7.x
      (see also !18682807!)

    6FC5357-0BB33-0AA0

      SW4.4 from V04.04.39
      SW5.3 from V05.03.42
      all SW6.x
      SW7.2 from 07.02.07


    Strategy in the spare parts business:

    NCU 572.3
    Predecessor  6FC5357-0BB22-0AE0  =>  successor  6FC5357-0BB23-0AA0

    NCU 573.3
    Predecessor  6FC5357-0BB33-0AE3  =>  successor  6FC5357-0BB33-0AA0

    If there is no compatibility with the NCU software, the previous component should be used – or if this is no longer available, then an upgrade should be made to the specified update status or to the next higher update status in the meantime.

    Depending on the inventory in the spare parts loop, spare part supply, supply as exchange and/or repair will be considered.


    Strategy in the new part business:

    NCU 572.3  =>  NCU 572.4 (or NCU 572.5)
    Predecessor  6FC5357-0BB22-0AE0  =>  successor  6FC5357-0BB24-0AA0
                                                               or 6FC5357-0BB25-0AA0

    NCU 573.3  =>  NCU 573.4 (or NCU 573.5)
    Predecessor  6FC5357-0BB33-0AE3  =>  successor  6FC5357-0BB34-0AA0
                                                               or 6FC5357-0BB35-0AA0

    The NCU *.3 components have been cancelled/discontinued effective 30.09.2004. The new replacement components in the new part business will be NCUs with integrated PLCs with a higher perbance (NCU *.4 with integrated PLC 314C-2DP or NCU *.5 with integrated PLC 317-2DP):
     

    PLC beters

    315-2DP
    NCU *.3

    314C-2DP
    NCU *.4

    317-2DP
    NCU *.5

    Processing time in ms/kI (1 kI = 1024 instructions, corresponds to approx. 3 kbytes)
    - for bit commands (minimum)
    - for commands (minimum)
    Factor for cycle time for
    user programs 1)



    0.3
    1.0

    1



    0.1
    0.25

    0.35



    0.03
    0.1

    0.12

    PLC user memory in kbytes,
    basic version
    max. expansion


    96
    288


    96
    480


    128
    768

    No. of FBs, FCs

    Each 256

    Each 256

    2048 2)

    No. of DBs

    399

    399

    20472)

    No. of timers

    128

    256

    512

    No. of counters

    64

    256

    512

    I/O scope for cyclic process image

    Each 128

        Each 128

    Each 256

    I/O scope for the complete logical I/O address space

    Each 1024

    Each 1024

    Each 4096 3)

    Max. number of Profibus slaves

    63

    32

    125

     

    Comments:

    1)

    The increase in perbance refers to the computational perbance available. Depending on the technological/process-related conditions, this increase in perbance is included in the total result. A faster IPO clock cycle (as a result of faster processors) and lower PLC cycle times result, partially, in significantly improved technological/process-related results; e.g. shorter unit/clock cycle times, higher speeds for eccentric turning, higher feed rates for mould construction.

    2)

    The number specified is the upper address number that can be used; the maximum number of FBs, FCs and DBs is, as a total, 2048!
    Reserved addresses should be taken into account; refer to the current documentation.

    3)

    4096 additional I/O addresses are available and can be seen in STEP 7; however these addresses are reserved for future applications. For compatibility reasons, these addresses may not be used. 
    The diagnostic addresses (presently at the upper end 1023, 1022) must be appropriaby marshaled in the PLC project; refer to the current documentation.

    Brief instructions: (prerequisites: SIMATIC know-how; STEP 7)
    When changing-over from an NCU with PLC315-2DP to an NCU with PLC 314C-2DP or PLC317-2DP, in the hardware configuration in the module catalog, the matching Rack0 should be selected under "SIMATIC 300\SINUMERIK\810D / 840D".
    Further it should be checked as to whether a Profibus diagnostics block of A&D AS (FC125 or FB125) is used. These blocks must be brought up to the actual version (V4.9).

在线询盘/留言
  • 免责声明:以上所展示的信息由企业自行提供,内容的真实性、准确性和合法性由发布企业负责,本网对此不承担任何保证责任。我们原则 上建议您选择本网高级会员或VIP会员。