WIKA 232.30.063 switchGAUGE
带开关触点全不锈钢波登管压力表
Bourdon tube pressure gauge with switch contacts
Model 232.30.063, stainless steel safety version
switchGAUGE model 232.30.063
Applications
Control and regulation of industrial processes
Monitoring of plants and switching of electric circuits
For gaseous and liquid aggressive media that are not highly viscous or crystallising, also in aggressive ambience
Process industry: For the monitoring of gas cylinders and reducing regulators
Special features
High reliability and long service life
Up to 2 switch contacts per instrument
Gauges with inductive contacts for use in hazardous areas with ATEX approval
Gauges with electronic contacts for PLC applications
Gauges in safety version S3 (k)
Debion
Wherever the process pressure has to be indicated locally, and, at the same time, circuits are to be made or broken, the Model 232.30.063 switchGAUGE can be used.
Switch contacts (electrical alarm contacts) make or break an electric control circuit dependent upon the b of the instrument pointer. The switch contacts are adjustable over 80 % of the scale range and are mounted predominantly below the dial.
The instrument pointer (actual value pointer) moves freely across the entire scale range, independent of the setting. The set pointer can be adjusted using a removable adjustment key in the b.
Switch contacts consisting of several contacts can also be set to a single set point. Contact actuation is made when the actual value pointer travels beyond or below the desired set point.
As switch contacts magnetic snap-b contacts, Reed switch, inductive contacts - for requirements to ATEX - or electronic contacts for triggering a PLC are available.
For further inbation on the different switch contacts please see data sheet AC 08.01.
Standard version
Accuracy class
1.6
Scale ranges
0 … 4 to 0 … 400 bar
or all other equivalent vacuum or combined pressure and vacuum ranges
Pressure limitation
Steady: 3/4 x full scale value
Fluctuating: 2/3 x full scale value
Short time: full scale value
Not suitable for dynamic load cycles
Operating temperature
Ambient: -20 ... +60 °C
Medium: +100 °C maximum
Temperature effect
When the temperature of the measuring system deviates from the reference temperature (+20 °C):
max. ±0.4 %/10 K of full scale value
Process connection
Stainless steel 1.4571,
lower mount (LM) or lower back mount (LBM)
G ¼ B (male), 14 mm flats
Pressure element
Stainless steel 316L, C-type
Movement
Stainless steel
Dial
Aluminium, white, black lettering
Pointer
Instrument pointer: aluminium, black
Set pointer: red
Case
Stainless steel, with solid baffle wall and blow-out back
Window
Polycarbonate
Bezel ring
Cam ring (bayonet type), stainless steel
Electrical connection
Cable gland with 2 m cable
Ingress protection
IP 54 per EN 60529 / IEC 529
Switch contacts
Magnetic snap-b contact model 821
No control unit and no extra power supply required
Direct switching up to 230 V
Up to 2 switch contacts per measuring instrument
Inductive contact model 831
Long service life due to non-contact sensor
Additional control unit required
With corresponding control unit suitable for use in Zone 1(2 G) hazardous areas
Low reb on the display accuracy
Fail-safe switching at high switching rates
Insensitive to corrosion
Up to 2 switch contacts per measuring instrument
Electronic contact model 830 E
For direct triggering of a programmable logic controller(PLC)
No additional control unit required
Long service life due to non-contact sensor
Low reb on the display accuracy
Fail-safe switching at high switching rates
Insensitive to corrosion
Up to 2 switch contacts per measuring instrument
Reed switch model 851
No control unit and no extra power supply required
Direct switching up to 150 V, 0,5 A
Also suitable for direct triggering of a programmable logic controller (PLC)
Free from wear as without contact
Switching function
The switching function of the switch is indicated by function index 1, 2 or 3.
Model 8XX.1: Contact makes (clockwise rotary motion of the pointer)
Model 8XX.2: Contact breaks (clockwise rotary motion of the pointer)
Model 821.3: Change-over; one contact breaks and one contact makes simultaneously when pointer reaches set point
For further inbation please see data sheet AC 08.01,electrical switch contacts
Options
Other process connection
Inductive contacts also in safety version
Dual scale
Panel mounting flange, polished stainless steel
Surface mounting lugs on case, stainless steel
Electrical connection: Miniature connector
Ingress protection IP 65
Dimensions in mm
switchGAUGE model 232.30.063
Ordering inbation
Model / Nominal size / Type of contact and switching function / Scale range / Connection size / Connectionb / Options
欢迎致电咨询订购WIKA 232.30.063 switchGAUGE 带开关触点全不锈钢波登管压力表
电话:010-51669912 56291930 15910733293
传真:010-51669912
QQ:823377546 1491421115 2636968574