产品简介
WIKA432.56 带过压保护膜片式不锈钢电接点压力表
WIKA432.56 带过压保护膜片式不锈钢电接点压力表
产品价格:¥1000
上架日期:2013-09-13 14:36:08
产地:德国
发货地:北京
供应数量:不限
最少起订:1件
浏览量:142
资料下载:暂无资料下载
其他下载:暂无相关下载
详细说明

    WIKA 432.56.100-831.21

     带过压保护膜片式不锈钢电接点压力表

    Diaphragm pressure gauge

    with switch contacts
    Model 432.56,

    high overpressure safety up to 100 bar
    Model 432.36, safety version, high overpressure safety up to 400 bar



    Diaphragm pressure gauge model 432.56.100,
    high overpressure safety up to 40 bar, with switch
    contact model 831.21

     

      Applications
        

      Control and regulation of industrial processes at measuring points with increased overpressure and scale ranges from 0 … 25 mbar
      Monitoring of plants and switching of electric circuits
      For gaseous and liquid, aggressive and highly viscous or contaminated media, also in aggressive ambience
      Process industry: Chemical, petrochemical, power plants, mining, on- and offshore, environmental technology, machine building and general plant construction

     Special features

     

      High overpressure safety, optionally up to 40, 100 or 400 bar, due to bllic diaphragm cushion, without liquidfilled measuring cell
      Wide choice of special materials
      Also available with liquid-filled case for high dynamic pressure loads or vibrations
      Gauges with inductive contacts for use in hazardous areas with ATEX approval
      Gauges with electronic contact for PLC applications

     

      Debion


      Wherever the process pressure has to be indicated locally, and, at the same time, circuits are to be made or broken, the model 432.56 or 432.36 switchGAUGE can be used.


      Switch contacts (electrical alarm contacts) make or break an electric control circuit dependent upon the b of the instrument pointer. The switch contacts are adjustable over the full extent of the scale range (see DIN 16085), and are
    mounted predominantly below the dial, though also partly on top of the dial. The instrument pointer (actual value pointer) moves freely across the entire scale range, independent ofthe setting.


      The set pointer can be adjusted using a removable adjustment key in the b.


      Switch contacts consisting of several contacts can also be set to a single set point. Contact actuation is made when the actual value pointer travels beyond or below the desired set point.


      The pressure gauge is manufactured in accordance with DIN 16085 and fulfils all requirements of the relevant standards (EN 837-3) and regulations for the on-site display of the working pressure of pressure vessels.


      As switch contacts magnetic snap-b contacts, reed switches, inductive contacts - for requirements to ATEX - or electronic contacts for triggering a PLC are available.


      For further inbation on the different switch contacts please
    see data sheet AC 08.01.

     

      Standard version

      Nominal size in mm
      100, 160

      Accuracy class
      1.6

      Scale ranges
      0 ... 25 mbar to 0 ... 250 mbar (flange Ø 160 mm) 1)
      0 ... 400 mbar to 0 ... 40 bar (flange Ø 100 mm) 1)
      or all other equivalent vacuum or combined pressure and vacuum ranges

      Pressure limitation
      Steady: Full scale value
      Fluctuating: 0.9 x full scale value
      Overpressure safety
      40, 100 or 400 bar

      Permissible temperature
      Ambient: -20 … +60 °C

      Medium: +100 °C maximum

      Temperature effect
      When the temperature of the measuring system deviates from the reference temperature (+20 °C):
      max. ±0.8 %/10 K of full scale value

      Process connection with lower measuring flange
      Stainless steel 316L, G ½ B (male), 27 mm flats

      Pressure element
      ≤ 0.25 bar: Stainless steel 316L
      > 0.25 bar: NiCr-alloy (Inconel)

      Pressure chamber sealing
      FPM/FKM
      

      Movement
      Stainless steel

      Dial
      Aluminium, white, black lettering

      Pointer
      Instrument pointer: Aluminium, black
      Set pointer: red

      Case
      Stainless steel, gauges with liquid filling with compensating valve to vent case
      Model 432.56: with blow-out device
      Model 432.36: safety version with solid baffle wall and blow-out back

      Upper measuring flange
      ≤ 0.25 bar: Chrome steel
      > 0.25 bar: NiCr-alloy

      Window
      Laminated safety glass

      Bezel ring

      Cam ring (bayonet type), stainless steel

     Electrical connection
      Terminal box

      Ingress protection
      IP 54 per EN 60529 / IEC 529

     Switch contacts


     Magnetic snap-b contact model 821
      No control unit and no extra power supply required
      Direct switching up to 250 V, 1 A
      Up to 4 switch contacts per measuring instrument

     

      Inductive contact model 831
      Long service life due to non-contact sensor
      Additional control unit required (model 904)
      With corresponding control unit suitable for use in zone 1 /21 (2 GD) hazardous areas
      Low effect on the indication accuracy
      Fail-safe switching at high switching rates
      Insensitive to corrosion
      Up to 3 switch contacts per measuring instrument

     Electronic contact model 830 E
      For direct triggering of a programmable logic controller(PLC)
      2-wire system (option: 3-wire system)
      Long service life due to non-contact sensor
      Low effect on the indication accuracy
      Fail-safe switching at high switching rates
      Insensitive to corrosion
      Up to 3 switch contacts per measuring instrument

      Reed switch model 851
      No control unit and no extra power supply required
      Direct switching up to 250 V, 1 A
      Also suitable for direct triggering of a programmable logic controller (PLC)
      Free from wear as without contact
      Up to two change-over contacts per measuring instrument

      Switching function
      The switching function of the switch is indicated by function index 1, 2 or 3.
      Model 8xx.1: Contact makes (clockwise pointer motion)
      Model 8xx.2: Contact breaks (clockwise pointer motion)
      Models 821.3 and 851.3: Change over; one contact breaks and one contact makes simultaneously when pointer reaches set point
      

      For further inbation please see data sheet AC 08.01, electrical switch contacts

     

      Options
      Other process connection
      Sealings (model 910.17, see data sheet AC 09.08)
      Liquid filling (models 433.56, 433.36, ingress protection IP 65)
      Vacuum safe to -1 bar
      Max. medium temperature +200 °C
      Higher indication accuracy, class 1.0
      Open connecting flanges per DIN/ASME from DN 15 to DN 80 (preferred nominal bs DN 25 and 50 or DN 1" and 2"; see data sheet IN 00.10)
      Wetted parts made of special materials, high overpressure safety up to 10 bar(flange Ø 160 mm) or 40 bar (flange Ø 100 mm): PTFE (models 452.56, 452.36), Hasbloy, Monel, nickel, tantalum, titanium (accuracy class 2.5)
      Inductive contacts also in safety version (SN, S1N)

      Special version


     Model 432.36, high overpressure safety up to 400 bar
      Scale ranges:
      0 ... 25 mbar to 0 ... 250 mbar (flange Ø 190 mm)
      0 ... 400 mbar to 0 ... 40 bar (flange Ø 120 mm)
      Flange connecting screws: Steel, corrosion-protected

    CE conbity

      Pressure equipment directive
      97/23/EC, PS > 200 bar, module A, pressure accessory

     EMC directive
      2004/108/EC, EN 61326 emission (group 1, class B) and interference immunity (industrial application)

      ATEX directive 1)
      94/9/EC, II 2 G Ex ia IIC

      Approvals 1)
      ATEX, Design approval for connection to hazardous zone 0
      GOST, metrology/measurement technology, Russia
      GOST-R, import certificate, Russia
      KOSHA, ignition protection type „i“ - intrinsic safety, South Korea
      CRN, safety (e.g. electr. safety, overpressure, ...), Canada

     

     Certificates 1)
      2.2 test report per EN 10204 (e.g. state-of-the-art manufacturing, material proof, indication accuracy)
      3.1 inspection certificate per EN 10204 (e.g. material proof
    wetted parts bl component, indication accuracy)

     1) Option
      Approvals and certificates, see website

     

     

       Dimensions in mm
       switchGAUGE model 432.56.100, with switch contact model 821, 831 or 830 E

       

       switchGAUGE model 432.56.160, with switch contact model 821, 831 or830 E


        Option
        switchGAUGE model 432.36.100, with switch contact model 821, 831 or 830 E


       Option
        switchGAUGE model 432.36.160, with switch contact model 821, 831 or 830 E



        Dimensions in mm
        switchGAUGE model 432.56.100, with switch contact model 851.3 or 851.33



        switchGAUGE model 432.56.160, with switch contact model 851.3 or 851.33


       Option
        switchGAUGE model 432.36.100, with switch contact model 851.3 or 851.33



        Option
        switchGAUGE model 432.36.160, with switch contact model 851.3 or 851.33



        Ordering inbation
        Model / Nominal size / Overpressure safety up to ... bar / Scale range / Type of contact and switching function / Connection
    size / Options

     

     

    欢迎致电咨询订购WIKA 432.56.100-831.21 带过压保护膜片式不锈钢电接点压力表

    电话:010-51669912 56291930 15910733293

    传真:010-51669912

    QQ:823377546 1491421115 2636968574

    邮箱:sales@zoriver.cn

    公司官网:http://www.zoriver.cn      http://www.zoriver.com.cn 

在线询盘/留言
  • 免责声明:以上所展示的信息由企业自行提供,内容的真实性、准确性和合法性由发布企业负责,本网对此不承担任何保证责任。我们原则 上建议您选择本网高级会员或VIP会员。
    企业信息
    卓尔瑞华(北京)科技有限公司
    会员级别:
    ------------ 联系方式 ------------
    联系人:仇立新()
    联系电话:010-51669912
    联系手机:15910733293
    传真号码:010-51669912
    企业邮箱:2636968574@qq.com
    网址:bjzoriver.jdzj.com
    邮编:100078
    推荐供应
    0571-87774297