产品简介
Trafag,8718,8728,8738,气体密度继电器
Trafag,8718,8728,8738,气体密度继电器
产品价格:¥1000
上架日期:2013-05-29 13:39:13
产地:本地
发货地:北京
供应数量:不限
最少起订:1个
浏览量:224
资料下载:暂无资料下载
其他下载:暂无相关下载
详细说明
    类型: Trafag,8718,8728,8738,8748,气体密度继电器,极低温SF6气体密度控制器 联接型式: 螺纹
    型号: Trafag气体密度继电器,SF6气体密度控制器,8718,8728,8738,8748 精度等级: 1
    品牌: Trafag/瑞士 环境温度: -60-80(℃)
    加工定制: 公称直径: 100(mm)
    测量范围: 0-1.1(MPa)

    Trafag,8718,8728,8738,8748,气体密度继电器,极低温SF6气体密度控制器

    北极温度SF6气体密度继电器,SF6气体密度控制器

     

        Trafag8718,8728,8738,8748,SF6气体密度继电器基本参数

        压力范围:0...1 MPa (0...1000 kPa)

        使用最低温度:-60ºC (-65ºC)

        适用气体:SF6和其它气体

        精度等级:

          Reference pressure <650 kPa abs.: ± <10 kPa @ -30...+50°C
          Reference pressure >650 kPa abs.: ± <12 kPa @ -30...+50°C

       

        Trafag,8718,8728,8738,8748,气体密度继电器,极低温SF6气体密度控制器产品特点

    • Principle: Reference gas measurement参考气室测量原理
    • For arctic temperatures, -76 to 176°F可用于北极温度-76 to 176°F(-60-80度)
    • Exact switching following isochore精确的微动开关
    • Excellent vibration resistance优越的抗振性
    • No false alarms at low temperatures极低温下不存在任何误报警
    • Stainless steel or aluminum sensor不锈钢或铝传感器
    • Galvanically separated circuits分立电路
    • Switch point adjustment in factory工厂设定
    • High/Medium Voltage应用于GIS系统高中压范围
    •  
    • Trafag,8718,8728,8738,8748,气体密度继电器,极低温SF6气体密度控制器
    • 北极温度SF6气体密度继电器,SF6气体密度控制器

        Application
        High voltage technology

     

       Main characteristics

        Gas Density Monitor for SF6 and other gases
    ?  Principle:                     Reference gas measurement
    ?  Measuring range:               0...1.1 MPa (0...1100 kPa)
    ?  Output:                        floating change-over contact
    ?  Switch point:                  factory calibrated

       Main features
    ?  For arctic temperatures:  –60...+80°C
    ?  Switching signal in case of liquefb of gas
    ?  Exact switching following isochore
    ?  Excellent vibration resistance
    ?  No false alarms at low temperatures
    ?  Stainless steel sensor
    ?  Independent, galvanically separated circuits

     

       Ordering inbation





        Specifications

        Main characteristics

        Principle:                    Reference gas measurement
        Measuring range absolut:      0...1.1 MPa(0...1100 kPa)
        Output:                       floating change-over contact
        Switch point:                 adjustment in factory

       accuracy (@ 20°C)
        Reference pressure <650 kPa abs.: ± <10 kPa
                                      @ -30...+50°C
        Reference pressure >650 kPa abs.: ± <12 kPa
                                      @ -30...+50°C

       accuracy of indicator
        SF6 Indicator dial
          Accuracy of indicator within numeralised
          range:                      ± 10 kPa @ 20°C
        Low pressure indicator
          Accuracy of indicator within numeralised
          range:
            @ 0 kPa relative:         ± 20 kPa
            >200 kPa relative:        ± 10 %

     

       Micro switch
        Rating:                       see table
        Resistance of insulation:     > 2 MΩ
        Dielectric strenght:          2 kV terminal to ground
        Life time (mechanical)
          micro switch 20:            1 Mio. cycles
        max. difference from the lowest to the highest
          switch point:               130kPa
        Switching differential typ.
          micro switch 20:            <15 kPa
            for indicating range or switching distance
            > 80 kPa:                 <15 kPa

       Electrical connection
        Screwed cable gland:          see accessories
        Terminal screw:               plugable, 0.2...2.5 mm2

       Environmental conditions
        Ambient temperatur:           –60...+80°C
        Media temperature             –60...+80°C
        Protection:                   IP65
        Humidity:                     max. 95% relative
        Vibration
          Min. Difference from switch point: 5 kPa
          20...80 Hz:                  4 g

        Choc:                          50g/ 11ms


       Mechanical daTA
        Material
          Measurement system:
            Sensor:                   1.4435,1.4404, 1.4401(AISI316L, AISI316)
            Sensor housing, options:  1.4435, 1.4404(AISI 316L)
            Filling:                  Gas
          Housing (density monitor):  AIS i10Mg
        Screwed cable gland: brass nickel plated
        Weight:                       ~ 800...1000 g
        pressure connection:         1.4404 (AISI 316L)(see data sheet H72502)

     

       Electrical data switch

       

        Protection








        Dimensions







        Dimensions





        verschiedene Gas-Druckanschlüsse siehe:
        différents raccords de pression pour gaz voir:
        different gas pressure connections see:
        Data sheet No: H72502

     

    欢迎致电咨询订购Trafag,8718,8728,8738,气体密度继电器,极低温SF6气体密度控制器

    电话:010-51669912 56291930 15910733293

    传真:010-51669912

    QQ:823377546 1491421115 2636968574

    邮箱:sales@zoriver.cn

    公司官网:http://www.zoriver.cn   http://www.zoriver.com.cn

     

在线询盘/留言
  • 免责声明:以上所展示的信息由企业自行提供,内容的真实性、准确性和合法性由发布企业负责,本网对此不承担任何保证责任。我们原则 上建议您选择本网高级会员或VIP会员。
    0571-87774297